R32 split heat pump 9kw

Guangdong Y.K.R New Energy Co., Ltd. is an Air-Source Heat Pump manufacturer specializing in R&D, manufacturing, and sales of all types of heat pump products for Industrial, Commercial, and Residential applications.

  • Commodity name: R32 split heat pump 9kw


You can send us an email:doris@ykr-e.com

Inquire Now
R32 split heat pump 9kw
R32 split heat pump 9kw
R32 split heat pump 9kw
R32 split heat pump 9kw
R32 split heat pump 9kw
+
  • R32 split heat pump 9kw
  • R32 split heat pump 9kw
  • R32 split heat pump 9kw
  • R32 split heat pump 9kw
  • R32 split heat pump 9kw

Product Details


  • Products Detail
  • Description
    • Commodity name: R32 split heat pump 9kw

     

    Model   YK-03/BPKTR3-F YK-04/BPKTR3-F YK-03/BPKTR3-F-S YK-04/BPKTR3-F-S
    Power Supply VHz/Ph 220-240/50-60/1 220-240/50-60/1 380-415/50-60/3N 380-415/50-60/3N
    Heating1 Max.Heating Capacity kW 9.1  12  9.1  12 
    COP WN 4.5  4.48  4.5  4.48 
    Heating Capacity Min/Max kW 4.0/9.1 5.3/12 4.0/9.1 5.3/12
    Heating power Input
        Min./Max
    kW 0.727/2.02 0.97/2.68 0.727/2.02 0.97/2.68
    COP Min/Max. WW 4.5/5.5 4.48/5.46 4.5/5.5 4.48/5.46
    Heating2 Max.Heating Capacity kW 8.5  11.1  8.5  11.1 
    COP WW 3.6  3.58  3.6  3.58 
    Heating Capacity Min/Max kW 3.8/8.5 4.8/11.1 3.8/8.5 4.8/11.1
    Heating power Input
        Min./Max.
    kW 0.863/2.36 1.1/3.1 0.863/2.36 1.1/3.1
    COP Min/Max. WW 3.6/4.4 3.58/4.35 3.6/4.4 3.58/4.35
    Cooling1 Max.Cooling Capacity kW 8.2  10.8  8.2  10.8 
    EER WW 3.45  3.42  3.45  3.42 
    Cooling Capacity Min/Max kW 3.6/8.2 4.6/10.8 3.6/8.2 4.6/10.8
    Cooling Power Input
        Min./Max.
    kW 0.878/2.38 1.135/3.15 0.878/2.38 1.135/3.15
    EER Min./Max. WW 3.45/4.1 3.42/4.05 3.45/4.1 3.42/4.05
    Cooling2 Max.Cooling Capacity kW 6.6  8.7  6.6  8.7 
    EER WW 2.8  2.78  2.8  2.78 
    Cooling Capacity Min/Max kW 3.05/6.6 3.92/8.7 3.05/6.6 3.92/8.7
    Cooling Power Input
        Min./Max.
    kW 0.871/2.35 1.12/3.12 0.871/2.35 1.12/3.12
    EER Min./Max. WW 2.8/3.5 2.78/3.48 2.8/3.5 2.78/3.48
    Rated Current A 9  11.9  3  4 
    Max   Current A 14.5  19  5  6.6 
    SCOP Level(35°℃)   A+++ A+++ A+++ A+++
    SCOP Level(55°℃)   A++ A++ A++ A++
    Working Ambient Temperature ℃   -38~43  
    Operating Water Temperature C   7~60  
    Refrigerant     R32  
    Compressor Type-Quantity/System   Twin Rotary-1 Twin Rotary -1 Twin Rotary-1 Twin Rotary-1
    Fan Quantity   1  1  1  1 
    Airflow m³/h 3000  3300  3000  3300 
    Rated power W 90  100  90  100 
    Water Side
    Heat Exchanger
    Type   Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger
    Water Pressure Drop kPa 20  23  20  23 
    Piping Connection inch G1" G1" G1" G1"
    Allowable Water
          Flow
                  
    Min./Rated./Max. m³/h 0.95/1.6/1.8 1.3/2.1/2.4 0.95/1.6/1.8 1.3/2.1/2.4
    Noise Level dB(A) 53  54  53  54 
    Outdoor Unit Size(LxDxH) mm 1125×430×824 1125×430×824 1125×430×824 1125×430×824
    Outdoor Packing Size(LxDxH) mm 1130×440×960 1130×440×960 1130×440×960 1130×440×960
    Indoor Unit Size(LxDxH) mm 655×450×220 655×450×220 655×450×220 655×450×220
    Indoor Packing Size(LxDxH) mm 661×460×255 661×460×255 661×460×255 661×460×255
    Outdoor unit Weight kg 75  75  77  77 
    Outdoor Gross Weight kg 84  84  86  86 
    Indoor Net Weight kg 30  30  30  30 
    ndoor Gross Weight kg 33  33  33  33 
     
    Model   YK-05/BPKTR3-F YK-06/BPKTR3-F YK-05/BPKTR3-F-S YK-06/BPKTR3-F-S
    Power Supply V/Hz/Ph 220-240/50-60/1 220-240/50-60/1 380-415/50-60/3N 380-415/50-60/3N
    Heating1 Max Heating Capacity kW 15  18.6  15  18.6 
    COP W 4.5  4.47  4.5  4.47 
    Heating Capacity Min./Max kW 6.6/15 8.2/18.6 6.6/15 8.2/18.6
    Heating power Input
    Min./Max
    kW 1.2/3.33 1.5/4.16 1.2/3.33 1.5/4.16
    COP Min./Max. WW 4.5/5.5 4.47/5.45 4.5/5.5 4.47/5.45
    Heating2 Max Heating Capacity kW 14  17.3  14  17.3 
    COP WI 3.6  3.56  3.6  3.56 
    Heating Capacity Min./Max kW 6.1/14 7.6/17.3 6.1/14 7.6/17.3
    Heating power Input
    Min./Max.
    kW 1.39/3.89 1.75/4.85 1.39/3.89 1.75/4.85
    COP Min./Max. WI 3.6/4.4 3.57/4.34 3.6/4.4 3.5714.34
    Cooling1 Max Cooling Capacity KW 13.5  16.7  13.5  16.7 
    EER WIW 3.45  3.42  3.45  3.42 
    Cooing Capacity Min./Max KW 5.8/13.5 7.2/16.7 5.8/13.5 7.2/16.7
    Cooling Power Input
    Min./Max.
    KW 1.41/3.91 1.77/4.88 1.41/3.91 1.77/4.88
    EER Min./Max. W 3.45/4.09 3.42/4.06 3.45/4.09 3.42/4.06
    Cooling2 Max Cooling Capacity kW 10.9  13.5  10.9  13.5 
    EER WI 2.79  2.78  2.79  2.78 
    Cooing Capacity Min./Max KW 4.9/10.9 6.1/13.5 4.9/10.9 6.1/13.5
    Cooling Power Input
    Min./Max
    kW 1.4/3.90 1.76/4.85 1.4/3.90 1.76/4.85
    EER Min.Max. W 2.79/3.5 2.78/3.46 2.79/3.5 2.78/3.46
    Rated Current A 15  18.5  5  6.2 
    Max Current A 24.5  30  8.2  10 
    SCOP Level(35℃)   A+++ A+++ A+++ A+++
    SCOP Level(55℃)   A++ A++ A++ A++
    Working Ambient Temperature ℃   -38~43  
    Operating Water Temperature ℃ 7~60  
    Refrigerant   R32  
    Compressor Type-Quantity/System   Twin Rotary-1 Twin Rotary-1 Twin Rotary-1 Twin Rotary-1
    Fan Quantity   2  2  2  2 
    Airflow m³/h 6000  6500  6000  6500 
    Rated power W 180  200  180  200 
    Water Side
    Heat Exchanger
    Type   Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger Plate Heat Exchanger
    Water Pressure Drop kPa 25  28  25  28 
    Piping Connection inch G1" G1" G1" G1"
    Allowable Water
        Flow                                                  
    Min./Rated./Max. m³/h 1.5/2.6/3.0 1.9/3.2/3.9 1.5/2.6/3.0 1.9/3.2/3.9
    Noise Level dB(A) 56  57  56  57 
    Outdoor Unit Size(LxDxH) mm 1137×445×1350 1137×445×1350 1137×445×1350 1137×445×1350
    Outdoor Packing Size(LxDxH) mm 1140×450×1390 1140×450×1390 1140×450×1390 1140×450×1390
    Indoor Unit Size(LxDxH) mm 655×450×220 655×450×220 655×450×220 655×450×220
    Indoor Packing Size(LxDxH) mm 661×460×255 661×460×255 661×460×255 661×460×255
    Outdoor unit Weight kg 117  126  117  126 
    Outdoor Gross Weight kg 128  137  128  137 
    Indoor Net Weight kg 33  34  33  34 
    Indoor Gross Weight kg 36  37  36  37 

     