household air conditioner

Guangdong Y.K.R New Energy Co., Ltd. is an Air-Source Heat Pump manufacturer specializing in R&D, manufacturing, and sales of all types of heat pump products for Industrial, Commercial, and Residential applications.

  • Commodity name: household air conditioner


You can send us an email:doris@ykr-e.com

Inquire Now
household air conditioner
household air conditioner
household air conditioner
+
  • household air conditioner
  • household air conditioner
  • household air conditioner

Product Details


 

Y.K.R New Effiency DC Inverter Split Air Conditioner
Model YKR-09k YKR-12k YKR-18k YKR-24k
Picture
Basic Data
Type / Heating pump Heating pump Heating pump Heating pump
Control Type   Remote Controller Remote Controller Remote Controller Remote Controller
Declared Cooling Capacity W 2600(940~3300) 3400(1000~3770) 5100(1250-5910) 6810(1830~7800)
Declared Heating Capacity W 2610(940~3360) 3420(1000~3810) 5100(1250-6070) 6870(1850~7900)
Pdesignc W 2600 3400 5100 6800
SEER Declared W/W 6.1 6.1 6.1 6.1
Energy  Class / A++ A++ A++ A++
EER Declared W/W 3.15 3.01 3.23 3.11
COP Declared W/W 3.4 3.4 3.71 3.33
Pdesignh Average W 2000 2100 3800 4800
SCOP Average Declared W/W 4 4 4 4
Energy  Class(Average) / A+ A+ A+ A+
Declare Capacity(-10℃) W 1900 2000 3600 4500
Back Up Heating Capacity(-10℃) W 100 100 200 300
Pdesignh Warmer W 2200 2400 5000 5800
SCOP Warmer Declared W/W 5.1 5.1 5.1 5.1
Energy Class(Warmer) / A+++ A+++ A+++ A+++
Declare Capacity(2℃) W 2200 2400 5000 5800
Back Up Heating Capacity(2℃) W 0 0 0 0
Pdesignh Colder W 2000 2200 4000 4700
SCOP Colder Declared W/W 3.4 3.4 3.4 3.4
Energy Class(Colder) / A A A A
Declare Capacity(-22℃) BTU 1700 1900 3700 4400
Back Up Heating Capacity(-22℃) BTU 300 300 300 300
Annual Energy Consumption Cooling W 149 195 293 390
Average W 700 735 1330 1680
Warmer W 604 659 1373 1592
Colder W 1235 1359 2471 2903
Moisture Removal   1 1.2 1.5 1.8
Indoor Sound Power(S/H/M/L/Mute) dB(A) 50/47/43/35/32 50/47/43/35/32 53/50/47/43/36 54/51/48/44/40
Outdoor Sound Power dB(A) 60 60 65 67
Indoor Sound Pressure(S/H/M/L/Mute) dB(A) 40/37/33/25/22 40/37/33/25/22 43/41/38//35/27 44/41/38/34/30
Outdoor  sound pressure dB(A) 50 50 55 57
Electrical Data
Power Supply V/Hz/Ph 220-240V~/50Hz/1P 220-240V~/50Hz/1P 220-240V~/50Hz/1P 220-240V~/50Hz/1P
Power Supply Side / Outdoor Outdoor Outdoor Outdoor
Voltage Range V 165~265 165~265 165~265 165~265
Operating Current Cooling A 4.0(1.2~8.0) 5.8(1.5~9.0) 8.1(1.7~12.0) 10.7(2.3~12.3)
Heating A 3.8(1.2~9.0) 5.1(1.5~10.0) 7.0(1.7~13.0) 9.9(2.3~13.5)
Power Consumption Cooling W 825(240~1380) 1130(290~1500) 1580(330-2340) 2257(410~2824)
Heating W 767(240~1552) 1005(290~1720) 1374(340-2520) 2063(420~3005)
Refrigerating System
Refrigerant type/Charge/GWP/CO2 equivalent / R32/0.45kg/675/0.304tonnes R32/0.49kg/675/0.331tonnes R32/1kg/675/0.675tonnes R32/1.14kg/675/0.770tonnes
Compressor Type / Rotary Rotary Rotary Rotary
Model / 35W2ALLB9F#MC 35W2ALLB9F#MC KSN140D33UFZ3 C-6RZ146H3DBF
MFG / RECHI RECHI GMCC SANYO
Indoor Air Circulation Cooling/Heating m3/h 420/420 550/550 800/800 980/980
Indoor Fan Type   Cross Flow Cross Flow Cross Flow Cross Flow
Indoor Fan Speed S/H/M/L/Mute Cooling m3/h 1400/1300/1100/1000/900 1350/1200/1000/850/750 1400/1260/1050/870/800 1250/1200/1050/950/800
Heating m3/h 1400/1300/1100/1000/900 1250/1150/1000/900/800 1400/1260/1050/870/800 1250/1200/1050/950/800
Dry m3/h 1000 850 870 950
Sleep m3/h / / / /
Outdoor Fan Type   Propeller fan Propeller fan Propeller fan Propeller fan
Outdoor Air Circulation  m3/h 1700 1700 2600 3000
Outdoor Fan Speed(S/H/M/L/Mute)   Cooling:930/930/830/730/630 Cooling:1000/910/830/710/710 Cooling:910/830/710/630/450 Cooling:930/830/690/570/450
Heating:930/930/830/730/630 Heating:950/950/830/710/710 Heating:910/830/710/630/450 Heating:890/830/690/590/450
Connections Data
Connecting Wiring Core  x Size / 4×0.75mm² 4×0.75mm² 4×0.75mm² 4×0.75mm²
Expension Device / Capillary Capillary Capillary Capillary
Connecting Pipe Gas / 3/8" 3/8" 3/8" 1/2"
Liquid / 1/4" 1/4" 1/4" 1/4"
Others Data
Application Area m2 9~16 14~22 20~35 27~45
Max. Refrigerant Pipe Length    m 25 25 25 25
Max. Difference In Level          10 10 10 10
Operation Temperature Range             16-31 16-31 16-31 16-31
Ambient Temperature Range              Outdoor Cooling:-15-53/Heating:-20-30 Cooling:-15-53/Heating:-20-30 Cooling:-15-53/Heating:-20-30 Cooling:-15-53/Heating:-20-30
Indoor Cooling:17-32/Heating:0-30 Cooling:17-32/Heating:0-30 Cooling:17-32/Heating:0-30 Cooling:17-32/Heating:0-30
Net Dimensions(W x H x D) Indoor mm 698×255×190 777×250×201 910×294×206 1010×315×220
Outdoor mm 712×276×459 712×276×459 853×602×349 920×699×380
Net Weight Indoor kg 6.5 7.5 10 13
Outdoor kg 22 22 31 40
Packing Dimensions Indoor mm 764×325×257 840×315×260  979×372×277 1096×390×297
W/O Pipe (W x H x D)  Outdoor mm 765×310×481 765×310×481 890×628×385 960×732×400
W/I Pipe (W x H x D)   Outdoor mm / / 890×628×385 960×732×430
Gross Weight Indoor kg 8.5 10 13 16
Outdoor kg 24(w/o pipe) 24(w/o pipe) 34(w/o pipe) 43(w/o pipe)
25(w/i pipe) 25(w/i pipe) 36(w/i pipe) 46(w/i pipe)
Loading Capacity W/O Pipe 20'GP   372 350 210 160

Guangdong Y.K.R New Energy Co., Ltd. is an Air-Source Heat Pump manufacturer specializing in R&D, manufacturing, and sales of all types of heat pump products for Industrial, Commercial, and Residential applications.

Since 2008,Y.K.R keeps focus on heat pumps development until now owning 5 large-scale heat pump production lines spread across 20,000m2 workshop, with an annually production capacity more than 2800 sets. Our company currently employs 150+ seasoned production workers, 18+ senior technical engineers, and we obtained 80+ product patents.

As our slogan states , " For green energy and a comfortable life ,"Y.K.R has been focusing on continuous technological innovation to improve the quality of products and services and is committed to providing customers with high-quality air source products and the best green energy solutions.

Previous

Next

Previous

Next

File Download


Name

Time

Size

Input information to obtain data

By systematically retrieving and analyzing relevant input information, detailed and professional data can be obtained to support or meet specific needs or goals.

确认
%{tishi_zhanwei}%

Related Products